If a supplier reports zero defective parts in a trial, the number inspected determines how much the result tells a buyer. Fifty clean observations and six hundred clean observations both show a zero observed defect rate. Under a simple independent-trial model, their one-sided 95% upper limits for the underlying defect rate are about 5.82% and 0.50% respectively. That difference matters when an Australian manufacturer evaluates a proposed component or inspection process.
Decide what counts as one trial
Consider a buyer assessing dimensional conformity of a new fastener. The buyer and supplier first agree the drawing revision, the dimension, the gauge, the acceptance limit and how borderline readings will be treated. The sampling unit is one independently selected fastener. Measuring the same fastener six times checks measurement repeatability. It does not provide six independent observations of production quality. Likewise, sixty parts taken from one cavity immediately after adjustment tell the buyer little about the other cavities or the next shift.
Work backwards from the claim
For a process with a constant defect probability p, the probability of finding zero defects in n independent items is (1 − p)ⁿ. Set this probability to 0.05 and solve for p to obtain the one-sided 95% upper bound, 1 − 0.05^(1/n). For 50 items this is 0.05816. For 300 items it is 0.00994. To design a zero-failure demonstration around a 1% limit, solve n ≥ log(0.05) ÷ log(0.99) and round up. The smallest sample under those assumptions is 299.

Specify the confidence level and whether the bound is one-sided. A two-sided interval allocates probability differently and will give a different upper limit. Also write down what happens after the first defect. This particular zero-failure calculation no longer applies, even if another two hundred parts subsequently pass. Keep the failure in the dataset, investigate the cause and use a method that admits the observed failure count. A change in tooling or inspection settings creates a new condition to document.
The sample size cannot correct a biased test
If a production fault occurs only after a machine warms up, a bag taken during start-up can miss it regardless of how large the bag is. Spread selections across the production conditions named in the claim. Use a sampling frame that records date, run, batch or cavity as appropriate. If items within a run fail together, a simple independent-unit confidence calculation can be too optimistic. A production engineer may need a design that treats batches as the sampling units or analyses between-run variation.
The test method itself also matters. A gauge that misses shallow defects can deliver a long sequence of apparently clean parts. Before treating the inspection result as a production result, use suitable reference pieces and record how the method deals with borderline items. Keep a copy of the drawing or method revision with the result. If the vendor collected the data, identify the vendor’s role in the report so another party can decide whether to witness a repeat test.
What belongs in a supplier evidence pack
State the claim, allowed defect rate, confidence level, sample unit and sampling method before the run begins.
Identify the line, lots, shifts and tools represented. Include any excluded observations and the reasons, as well as every observed nonconformity.
Report both the observed count and the calculated upper bound, including the independence and stable-process assumptions.
Decide who will review failed or ambiguous cases and how the accepted production configuration will be identified on the purchase order.
This gives procurement a way to assess whether the arithmetic supports the claim and whether the trial actually represents the goods it intends to buy.
Sources and working data
The NIST engineering statistics handbook explains exact binomial intervals. The one-sided zero-failure calculation above follows directly from the probability of zero events. Download the sample-size comparison. For local calibration enquiries, use Industry Applied’s guide to Australian and New Zealand laboratory scopes.
Cover photograph by John Triwinata, published under the Pexels licence. The layout may crop the photograph. The worked example and chart are by Industry Applied.