Technology Outlook · Industrial Automation
A camera passed 98% of the test packs. Which ones did it miss?
A machine-vision trial needs separate counts for missed defects and rejected good packs. Build the test set around conditions the line actually sees.

A camera vendor reports 98% accuracy on a packaging trial. The production supervisor wants to know whether crooked labels will reach customers and how many good packs will go into the reject bin. One headline percentage cannot answer both questions. Keep a reference judgement for each test pack and track both kinds of error.
Build a trial the next shift can repeat
Set aside representative good packs and known defects. Include both shifts, substrate finishes and ordinary changes in lighting. Have the quality team establish the references independently. Keep the test images separate from those used to tune the system and record the approved model or rule version.
Imagine 180 good packs and 20 defective packs. The camera accepts 178 good packs, rejects two good ones, rejects 18 defective packs and accepts two defects. It classifies 196 of 200 correctly. Yet it misses 2 of the 20 known defects, or 10%, and falsely rejects 2 of 180 good packs, about 1.1%.

What to check on site
Keep the confusion counts by defect type, lighting and pack format.
Test the physical reject mechanism as well as the software output.
Agree acceptable error rates and an escalation path with the process owner.
A contract packer can use the trial to choose the next defect class to sample. Rare faults need enough examples to support an estimate, regardless of how many ordinary packs run through.
Sources and photograph
Australian National AI Centre — putting AI into practice
A camera vendor reports 98% accuracy on a packaging trial. The production supervisor wants to know whether crooked labels will reach customers and how many good packs will go into the reject bin. One headline percentage cannot answer both questions. Keep a reference judgement for each test pack and track both kinds of error.
Build a trial the next shift can repeat
Set aside representative good packs and known defects. Include both shifts, substrate finishes and ordinary changes in lighting. Have the quality team establish the references independently. Keep the test images separate from those used to tune the system and record the approved model or rule version.
Imagine 180 good packs and 20 defective packs. The camera accepts 178 good packs, rejects two good ones, rejects 18 defective packs and accepts two defects. It classifies 196 of 200 correctly. Yet it misses 2 of the 20 known defects, or 10%, and falsely rejects 2 of 180 good packs, about 1.1%.

What to check on site
Keep the confusion counts by defect type, lighting and pack format.
Test the physical reject mechanism as well as the software output.
Agree acceptable error rates and an escalation path with the process owner.
A contract packer can use the trial to choose the next defect class to sample. Rare faults need enough examples to support an estimate, regardless of how many ordinary packs run through.
Sources and photograph
Australian National AI Centre — putting AI into practice