Divide 95 kW of measured package input by the measured free-air delivery. At 14 on the delivered free-air flow (m³/min) scale, the worked result is 6.786 on the specific input power (kw per m³/min) scale. The figure and table let you check the result against a second operating point.

Set up the field measurement

Match the reference conditions of both flow reports and log discharge pressure. Compare equal air service over the same sampling period. Keep the reference observation alongside the calculation, with the instrument identification, observation period and units. This makes it possible for the next shift to distinguish a new operating condition from a change in how the observation was recorded.

Two operating points

Compare the two adjacent inputs of 12 and 14 m³/min. The calculation gives 7.917 at the first and 6.786 at the second. The signed change is -1.131 on the output scale. A spreadsheet cross-check should reproduce both rows and the direction of change before it is copied through the remaining conditions.

Specific input power (kW per m³/min) plotted against delivered free-air flow (m³/min). Across the example the output changes from 11.875 to 5.278.
Specific input power (kW per m³/min) plotted against delivered free-air flow (m³/min). Across the example the output changes from 11.875 to 5.278. Figure by Industry Applied.

Worked data

Delivered free-air flow (m³/min)

Specific input power (kW per m³/min)

8

11.875

10

9.5

12

7.916667

14

6.785714

16

5.9375

18

5.277778

Checking the working range

At the two ends of the example, an input of 8 gives 11.875 and an input of 18 gives 5.278. Use a value near each end to check your implementation. Testing only the middle row can conceal an incorrect offset, an inverted ratio or a unit conversion applied twice.

Interpreting the result

Including loaded power while averaging flow over loaded and unloaded intervals makes the ratio misleading. Integrate both quantities over the same window. If measured performance sits outside the worked range, first repeat the comparison using field inputs and the same boundary. Preserve the original reading in the export. A discrepancy is easier to investigate when the field observation and the calculated output occupy separate columns.

Source and calculation data

For the underlying measurement context, see the US Department of Energy compressed-air sourcebook. The operating values and sensitivity analysis here are an Industry Applied worked example. Download the input and output values to verify the calculation with the values from your own site.