Two plants can report different mean times between failures for the same operating record if one uses scheduled hours and the other uses actual running hours. Define what is exposed to failure, when an interruption starts and when useful service resumes. Keep the running time, restoration time and failure count in the report so another reader can reconstruct the indicators.

Reconcile one production period

Imagine one packaging machine scheduled to provide service for 100 hours. It operates for 96 hours, stops twice for counted failures and spends a total of four hours unavailable for those failures. Assume it was observed throughout the whole period, both events finished within the period and there were no planned stops. An operating-time estimate of mean time between failures is 96 ÷ 2 = 48 hours. Mean time to restore service for these two events is 4 ÷ 2 = 2 hours.

Observed availability over this example’s stated service window is 96 ÷ 100 = 96%. Under these matching definitions, 48 ÷ (48 + 2) also gives 96%. Substituting the full 100 scheduled hours into the operating-time numerator gives a different figure of 50 hours between failures. Combining that 50 with the two-hour restoration result would produce 96.15%, which no longer reconciles to the observed 96 out of 100 hours.

Four hours lost across two failures comprise 1.5 hours of hands-on repair and 2.5 other restoration hours. Mean restoration is two hours per event.
Four hours lost across two failures comprise 1.5 hours of hands-on repair and 2.5 other restoration hours. Mean restoration is two hours per event. Chart by Industry Applied.

Define restoration before comparing repair teams

Suppose the four hours of lost service comprised 90 minutes of hands-on work and 150 minutes of diagnosis, isolation, waiting for spares, verification and restart. A metric restricted to hands-on time would be 1.5 ÷ 2 = 0.75 hours per failure. A customer waiting for the line to resume experienced two hours per interruption on average. Label these measures according to the recorded boundaries. A plant can improve spare availability while making little change to actual tool time, and that improvement should show up in the appropriate measure.

For a multi-stage line, specify whether the asset is the complete line or one component. One upstream failure can stop several stations. Counting four stoppage alarms as four independent line failures changes the denominator without changing lost output. Preserve the failure event ID and the affected assets. If two independent faults overlap, avoid summing overlapping intervals twice when calculating whole-line unavailability.

Treat missing and unfinished intervals explicitly

Consider a ten-hour planned shutdown in the next reporting month. If the asset was not required to run during that interval, an availability measure defined over required service time can exclude it. If a commercial contract measures calendar availability, read its definitions before applying the same exclusion. Separate the scheduled service window, planned exclusions and observed failures in the report.

A fault still open at month end contributes observed unavailable time to that reporting window. Its complete restoration duration is unknown on the closing date. Explain how the restoration average treats the open event, and reconcile the carry-in and carry-out periods across months. A month with zero recorded failures has no finite empirical operating-time-per-failure point estimate under this simple division. Show the observed run hours and the zero count so the reader can judge the evidence.

Worked data

Measure

Value

Unit

Basis

Scheduled service

100

hours

Observed reporting window

Operating time

96

hours

Machine able to operate

Unavailable time

4

hours

Two failures in scope

Failure count

2

events

Two completed failures

MTBF estimate

48

hours per failure

96 / 2

Mean restoration

2

hours per failure

4 / 2

Observed availability

96

percent

96 / 100 x 100

Download the example’s time boundaries and indicators. The NIST reliability handbook describes operating-time and failure-count estimation under the constant-rate model. Atlassian compares repair, recovery and related incident measures. A two-event ledger is a worked reconciliation. It offers little evidence about a long-term failure rate without more operating history.

Cover photograph by Mikhail Nilov, published under the Pexels licence. The calculation, data and chart are by Industry Applied.