The middle half of the estimated payback periods ran from 0.13 to 1.0071 years for turning off equipment during breaks, reduce operating time, a spread of 0.87707 years. The median among 654 qualifying US proposals was 0.4133 years. Each proposal has equal weight.

The scope of the plant change

Define the work package in physical terms and identify which meter, production counter or invoice can capture its effect. Record a representative operating cycle before changing the process and retain the underlying unit prices alongside measured quantities.

A recommendation you can reproduce

Recommendation TT018804 in US fiscal year 2017 pairs US$890 of implementation cost with US$2,153 in estimated annual net savings. Dividing the first figure by the second gives 0.4134 years. This record was selected by proximity to the median payback, with the more recent assessment preferred when ratios tie.

The median implementation cost was US$632 and the median annual saving was US$2,073. Those two medians can come from different facilities. To obtain the payback distribution, divide cost by annual savings within each recommendation and take percentiles of the resulting years. Zero-cost measures remain in the calculation. The table selects actual records at five ordered positions, so its rounded examples can differ slightly from interpolated percentiles.

Estimated payback for turning off equipment during breaks, reduce operating time. Lower quartile 0.13, median 0.4133 and upper quartile 1.007 years.
Estimated payback for turning off equipment during breaks, reduce operating time. Lower quartile 0.13, median 0.4133 and upper quartile 1.007 years. Figure by Industry Applied.

What the records can support

The source lists 1,312 recommendations under assessment code 2.6212. The analysis retains records with a reported fiscal year, a non-negative implementation cost and positive net annual monetary savings. It sums the reported primary, secondary, tertiary and quaternary dollar savings, preserving recorded costs or offsets. A missing savings field contributes nothing only when at least one resource has a recorded value.

Of the 654 comparable records, 321 carry the implemented flag and 301 the non-implemented flag. The remaining 32 have another or unreported status. These are administrative outcomes. They do not establish the saving subsequently measured at an individual plant.

How the assessment mix affects the comparison

For fiscal years 1980–1999, 320 qualifying records had a median of 0.4487 years. For fiscal years 2000–2014, 148 qualifying records had a median of 0.2893 years. For fiscal years 2015–2026, 186 qualifying records had a median of 0.4622 years. Grouping by year changes the mix of facilities and proposals. The medians are descriptive, and the database does not establish a causal trend over time.

Worked data

Recommendation ID

US fiscal year

Implementation cost (USD)

Estimated annual net saving (USD)

Recalculated payback (years)

TT020501

2018

20

376439

5.312946e-05

WM001203

2012

100

771

0.1297017

CO008905

1987

300

726

0.4132231

AM009809

1990

700

695

1.007194

SD004006

1992

7150

265

26.98113

Using the evidence in an Australian project

For the worked record, delivering only three quarters of its estimated annual saving would give 0.5512 years. At full forecast savings and a 20% higher installed cost, it would give 0.4961 years. These are sensitivity calculations using the same original proposal. A local business case needs quotations and a current Australian tariff or material price.

Run the local comparison over the same production duty in both cases. Keep a separate column for incentives, scheduled replacement and avoided maintenance so that the engineering change can be evaluated at both full and incremental cost.

What a two-year screening rule would have selected

Among the 654 proposals with a positive implementation cost, 590 (90.214%) had a forecast simple payback of two years or less. The calculation excludes 0 zero-cost records. For a local project with a two-year screening period, divide the quoted installed cost by two to find the minimum annual net saving needed. Use local currency and include the recurring cost of making the change.

Sources and calculation files

The assessment-code results and the US Industrial Training and Assessment Centers database download contain the original recommendations. Dollar amounts are nominal US dollars for the assessment year. The Australian Government equipment guides provide local context. Download the worked records as CSV.