For equal air temperature, multiply receiver volume by a 150 kPa pressure difference divided by 100 kPa ambient absolute pressure. At 2 on the receiver internal volume (m³) scale, the worked result is 3 on the approximate usable free air (m³) scale. The figure and table let you check the result against a second operating point.

Set up the field measurement

Confirm local ambient pressure and the receiver's actual pressure swing while air is being drawn. The pressure difference can use gauge readings on the same basis. Keep the reference observation alongside the calculation, with the instrument identification, observation period and units. This makes it possible for the next shift to distinguish a new operating condition from a change in how the observation was recorded.

Two operating points

Compare the two adjacent inputs of 1 and 2 m³. The calculation gives 1.5 at the first and 3 at the second. The signed change is 1.5 on the output scale. A spreadsheet cross-check should reproduce both rows and the direction of change before it is copied through the remaining conditions.

Approximate usable free air (m³) plotted against receiver internal volume (m³). Across the example the output changes from 0.375 to 7.5.
Approximate usable free air (m³) plotted against receiver internal volume (m³). Across the example the output changes from 0.375 to 7.5. Figure by Industry Applied.

Worked data

Receiver internal volume (m³)

Approximate usable free air (m³)

0.25

0.375

0.5

0.75

1

1.5

2

3

3

4.5

5

7.5

Checking the working range

At the two ends of the example, an input of 0.25 gives 0.375 and an input of 5 gives 7.5. Use a value near each end to check your implementation. Testing only the middle row can conceal an incorrect offset, an inverted ratio or a unit conversion applied twice.

Interpreting the result

Rapid withdrawals cool the vessel and reduce the validity of the isothermal model. The result describes air storage and does not establish vessel design suitability. If measured performance sits outside the worked range, first repeat the comparison using field inputs and the same boundary. Preserve the original reading in the export. A discrepancy is easier to investigate when the field observation and the calculated output occupy separate columns.

Source and calculation data

For the underlying measurement context, see the US Department of Energy compressed-air sourcebook. The operating values and sensitivity analysis here are an Industry Applied worked example. Download the input and output values to verify the calculation with the values from your own site.