Divide 2.4 cubic metres of usable free air between the allowed operating setpoints by demand at the same reference conditions. In the worked example, Free-air demand of 0.8 m³/min gives buffer duration of 3 min.
Set up the field measurement
Measure the temporary peak downstream of the receiver, including coincident tools. Account for any compressor that keeps delivering air during the event. Keep the reference observation alongside the calculation, with the instrument identification, observation period and units. This makes it possible for the next shift to distinguish a new operating condition from a change in how the observation was recorded.
Two operating points
At 0.6 m³/min the calculated buffer duration is 4 min. At 0.8 m³/min it is 3 min. Subtracting the first output from the second gives -1 min. These values give two independent checkpoints for a spreadsheet or a logger conversion.

Worked data
Free-air demand (m³/min) | Buffer duration (min) |
|---|---|
0.3 | 8 |
0.4 | 6 |
0.6 | 4 |
0.8 | 3 |
1.2 | 2 |
2.4 | 1 |
Checking the working range
At the two ends of the example, an input of 0.3 gives 8 and an input of 2.4 gives 1. Use a value near each end to check your implementation. Testing only the middle row can conceal an incorrect offset, an inverted ratio or a unit conversion applied twice.
Interpreting the result
A large stored volume cannot overcome an undersized connection. Check downstream pressure during a real peak before crediting the whole calculated duration. If measured performance sits outside the worked range, first repeat the comparison using field inputs and the same boundary. Preserve the original reading in the export. A discrepancy is easier to investigate when the field observation and the calculated output occupy separate columns.
Source and calculation data
For the underlying measurement context, see the US Department of Energy compressed-air sourcebook. The operating values and sensitivity analysis here are an Industry Applied worked example. Download the input and output values to verify the calculation with the values from your own site.