Divide a delivery of 0.018 cubic metres per second by the circular flow area using actual bore. In the worked example, Actual internal diameter of 100 mm gives mean water velocity of 2.2918 m/s.
Set up the field measurement
Use a measured bore or a documented internal diameter for the exact pipe and lining. Nominal size can differ materially from the water passage. Keep the reference observation alongside the calculation, with the instrument identification, observation period and units. This makes it possible for the next shift to distinguish a new operating condition from a change in how the observation was recorded.
Two operating points
At 90 mm the calculated mean water velocity is 2.8294 m/s. At 100 mm it is 2.2918 m/s. Subtracting the first output from the second gives -0.53759 m/s. These values give two independent checkpoints for a spreadsheet or a logger conversion.

Worked data
Actual internal diameter (mm) | Mean water velocity (m/s) |
|---|---|
65 | 5.424452 |
80 | 3.580986 |
90 | 2.829421 |
100 | 2.291831 |
125 | 1.466772 |
150 | 1.018592 |
Checking the working range
At the two ends of the example, an input of 65 gives 5.424 and an input of 150 gives 1.019. Use a value near each end to check your implementation. Testing only the middle row can conceal an incorrect offset, an inverted ratio or a unit conversion applied twice.
Interpreting the result
Velocity is a cross-sectional mean. It does not by itself specify a suitable meter installation, pressure loss or acceptable operating speed. If measured performance sits outside the worked range, first repeat the comparison using field inputs and the same boundary. Preserve the original reading in the export. A discrepancy is easier to investigate when the field observation and the calculated output occupy separate columns.
Source and calculation data
For the underlying measurement context, see the US Department of Energy pumping systems sourcebook. The operating values and sensitivity analysis here are an Industry Applied worked example. Download the input and output values to verify the calculation with the values from your own site.