Divide useful hydraulic power at 18 m head by 12 kW simultaneous electrical input. Use 1,000 kg per cubic metre for water. In the worked example, Measured flow of 25 L/s gives wire-to-water efficiency of 36.775 %.
Set up the field measurement
Use pressure taps and flow readings representative of the water delivered to the service boundary. Meter the entire motor and drive supply on the same interval. Keep the reference observation alongside the calculation, with the instrument identification, observation period and units. This makes it possible for the next shift to distinguish a new operating condition from a change in how the observation was recorded.
Two operating points
At 20 L/s the calculated wire-to-water efficiency is 29.42 %. At 25 L/s it is 36.775 %. Subtracting the first output from the second gives 7.355 %. These values give two independent checkpoints for a spreadsheet or a logger conversion.

Worked data
Measured flow (L/s) | Wire-to-water efficiency (%) |
|---|---|
10 | 14.70998 |
15 | 22.06496 |
20 | 29.41995 |
25 | 36.77494 |
30 | 44.12993 |
40 | 58.8399 |
Checking the working range
At the two ends of the example, an input of 10 gives 14.71 and an input of 40 gives 58.84. Use a value near each end to check your implementation. Testing only the middle row can conceal an incorrect offset, an inverted ratio or a unit conversion applied twice.
Interpreting the result
Bypassed flow can lift the apparent result without supplying useful water. State how much flow reaches the required delivery point. If measured performance sits outside the worked range, first repeat the comparison using field inputs and the same boundary. Preserve the original reading in the export. A discrepancy is easier to investigate when the field observation and the calculated output occupy separate columns.
Source and calculation data
For the underlying measurement context, see the US Department of Energy pumping systems sourcebook. The operating values and sensitivity analysis here are an Industry Applied worked example. Download the input and output values to verify the calculation with the values from your own site.