Compare compressor packages at the air demand and pressure your plant actually uses. Add the electrical energy drawn over each part of a representative shift, then divide by the total free-air volume delivered on the same reference basis. A machine with the better full-load number can consume more electricity when the plant spends much of the day at low demand.

Establish the measurement boundary

At an Australian packaging plant the air header might serve production tools, packing machines and occasional cleaning loads. Define the boundary before collecting figures. A compressor package input meter includes the electrical loads within its metering boundary. A plant-room meter may also include a dryer, cooling pumps or another compressor. A flow reading taken downstream of the dryer can differ from an upstream reading if purge or other losses occur between them.

Record the stated discharge pressure, the reference conditions used for flow and whether the vendor quotes free-air delivery or the actual volume in a pressurised line. A cubic metre of compressed air at line conditions represents a different amount of gas from a cubic metre referred back to intake conditions. A regulator setting is insufficient to convert between them. Obtain the meter configuration and the supplier’s reference terms before combining its readings with a package datasheet.

A two-load shift changes the ranking

Take two hypothetical packages operating at the same required discharge pressure. Demand is 6 m³/min for four hours and 2 m³/min for four hours. On this shared free-air basis the shift needs 6 × 240 + 2 × 240 = 1,920 m³. Package A draws 42 kW at high load and 25 kW at low load. Package B draws 45 kW and 17 kW respectively. Both deliver the required flow throughout the example.

At high load A has the lower specific power, 42 ÷ 6 = 7.0 kW per m³/min, compared with 7.5 for B. Across the shift, A draws 42 × 4 + 25 × 4 = 268 kWh. B draws 248 kWh. The energy intensities are about 0.140 and 0.129 kWh per delivered cubic metre. Package B uses 20 kWh less across this duty, about 7.5% of A’s shift energy. These figures illustrate a comparison method. They are not measurements of a particular compressor.

At equal pressure and flow, packages A and B use 268 and 248 kWh over an illustrative four-high, four-low-hour shift. Their energy curves cross at 5.82 high-load hours.
At equal pressure and flow, packages A and B use 268 and 248 kWh over an illustrative four-high, four-low-hour shift. Their energy curves cross at 5.82 high-load hours. Chart by Industry Applied.

Find the point where the decision reverses

For each high-load hour A saves 3 kWh versus B. For each low-load hour it uses an extra 8 kWh. On an eight-hour shift their totals are equal when 3 × high-load hours = 8 × low-load hours. That gives about 5.82 high-load hours and 2.18 low-load hours. Put a second shift beside the first before signing a purchase order. A plant that spends seven hours a shift at high output can reach a different choice from the four-hour example.

Pressure drift and receiver inventory can distort a short trial. Log pressure and flow over the same period as power and compare the start and finish conditions. A falling receiver pressure can temporarily supply air that the running machine never produced during the test. Capture no-production periods as well. A package that draws appreciable power while delivering very little air can materially change the weekly result.

Tell suppliers what the tender will compare

Ask for input power and free-air delivery at the stated pressure across the required operating range. Record which auxiliaries are included and obtain the data sheet for the actual model. Match the proposed duty to the working pressure needed at the end use. Separate observed energy, illustrative tariff assumptions and capital cost in the investment review.

Australia’s energy equipment guide covers compressed-air systems. The Compressed Air and Gas Institute’s example datasheet identifies pressure, capacity and package power. Download the eight-hour comparison.

Cover photograph by Mazhar Ulazhar, published under the Pexels licence. The worked figures and chart are by Industry Applied.