Manufacturing · Industrial Automation
What is still using compressed air after shutdown?
A weekend meter trace can put a number on unexplained air use. Separate legitimate overnight demand before putting a dollar figure on leaks.

At a packaging works the last sealer stops at six, yet the compressor cycles all night. Maintenance suspects leaks. A useful first measurement is the flow leaving the compressor room during a period when production is known to be idle. A power trace alone is harder to interpret because compressors use power differently while unloaded.
Measure one quiet operating window
Choose a production-free window, note the header pressure and record any equipment that still draws air. An instrument purge, dryer or automated drain may be a legitimate continuous user. Record meter units and the reference conditions for any standardised volume. Keep the same pressure and meter boundary for the follow-up test.
Suppose an Australian packing shed records 42 m³/h on its supply meter for six hours. A separately measured purge takes 12 m³/h on the same reference basis. The unexplained rate is 30 m³/h, or 180 m³ over the test. That is a survey target. Locating leaks and recording a comparable second test will show how much of it was recoverable.

What to check on site
Log compressor state and header pressure alongside flow.
Identify overnight users with the production supervisor and measure large ones individually.
Prioritise repairs by measured flow and access, then repeat the quiet-window test.
To estimate electricity savings, use the change in compressor input kWh over matched periods. Multiplying lost air by a catalogue efficiency can overstate the return when an unloaded machine keeps running.
Sources and photograph
Australian Government — compressed air systems
At a packaging works the last sealer stops at six, yet the compressor cycles all night. Maintenance suspects leaks. A useful first measurement is the flow leaving the compressor room during a period when production is known to be idle. A power trace alone is harder to interpret because compressors use power differently while unloaded.
Measure one quiet operating window
Choose a production-free window, note the header pressure and record any equipment that still draws air. An instrument purge, dryer or automated drain may be a legitimate continuous user. Record meter units and the reference conditions for any standardised volume. Keep the same pressure and meter boundary for the follow-up test.
Suppose an Australian packing shed records 42 m³/h on its supply meter for six hours. A separately measured purge takes 12 m³/h on the same reference basis. The unexplained rate is 30 m³/h, or 180 m³ over the test. That is a survey target. Locating leaks and recording a comparable second test will show how much of it was recoverable.

What to check on site
Log compressor state and header pressure alongside flow.
Identify overnight users with the production supervisor and measure large ones individually.
Prioritise repairs by measured flow and access, then repeat the quiet-window test.
To estimate electricity savings, use the change in compressor input kWh over matched periods. Multiplying lost air by a catalogue efficiency can overstate the return when an unloaded machine keeps running.
Sources and photograph
Australian Government — compressed air systems