The recorded err[1].y channel spans -1.55e-07 to 4.16e-07 source units in this reference run. It starts at -1.55e-07 and ends at 4.16e-07. The first recorded maximum occurs at 100,000 seconds and the first minimum at 0 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named ZoneWithInputsValidationLinear. The source file places it under LIDEAS. We used the 101 stored values for err[1].y over the interval 0 to 100,000 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 6 recorded variables. Alongside the primary output there are TZon_ssm[1].y, TZon[1].y, TZon_ssm[2].y, TZon[2].y, err[1].y. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel err[2].y covers 1.51e-08 to 1.08e-06 source units. At 100,000 s, the primary value is 4.16e-07 and the companion is 1.08e-06. Their signed difference is -6.62e-07 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Zone with inputs linear. The simulated err[1].y channel runs from -1.55e-07 to 4.16e-07 source units over 100,000 seconds.
Zone with inputs linear. The simulated err[1].y channel runs from -1.55e-07 to 4.16e-07 source units over 100,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 1,000 seconds. Subtracting -1.55e-07 from -1.33e-07 gives 2.27e-08 source units. Its location brackets the change within one saved interval of 1,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

err[1].y (source units)

err[2].y (source units)

0

-1.552439e-07

1.511205e-08

1000

-1.325644e-07

1.042123e-07

20000

4.026992e-08

5.017758e-07

40000

1.469706e-07

6.741345e-07

60000

2.430263e-07

8.306336e-07

80000

3.322052e-07

9.626658e-07

100000

4.160243e-07

1.078452e-06

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.