The recorded zone.phi channel spans 0.6703 to 1.171 source units in this reference run. It starts at 0.692 and ends at 0.865. The first recorded maximum occurs at 63,000 seconds and the first minimum at 18,000 seconds.
The system being tested
The KU Leuven IDEAS project publishes the IDEAS test named ZoneWithSources. The source file places it under Buildings. We used the 101 stored values for zone.phi over the interval 0 to 100,000 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name zone (Simple Zone), pulse (Pulse). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel zone.ppm covers 400 to 3,168 source units. At 27,000 s, the primary value is 0.9532 and the companion is 3,168. Their signed difference is -3,167 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 99,000 to 100,000 seconds. Subtracting 1.1 from 0.865 gives -0.2347 source units. Its location brackets the change within one saved interval of 1,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | zone.phi (source units) | zone.ppm (source units) |
|---|---|---|
0 | 0.6920282 | 400 |
18000 | 0.670319 | 1418.108 |
20000 | 0.8860037 | 2876.563 |
40000 | 0.8220661 | 1969.624 |
60000 | 1.058341 | 2383.088 |
63000 | 1.17128 | 3167.608 |
80000 | 0.962339 | 2411.223 |
99000 | 1.099662 | 3167.612 |
100000 | 0.8649569 | 1987.932 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.
