The recorded case900Template.TSensor channel spans 280.187 to 293.15 source units in this reference run. It starts at 293.15 and ends at 281.102. The first recorded maximum occurs at 0 seconds and the first minimum at 900,000 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named ZoneTemplateVerification2. The source file places it under Buildings, Tests. We used the 101 stored values for case900Template.TSensor over the interval 0 to 1,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name win (Window). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 18.8% of its saved checkpoints at or above 286.668 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 283.755 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Zone template verification2. The simulated case900Template.TSensor channel runs from 280.187 to 293.15 source units over 1,000,000 seconds.
Zone template verification2. The simulated case900Template.TSensor channel runs from 280.187 to 293.15 source units over 1,000,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 120,000 to 130,000 seconds. Subtracting 284.841 from 288.607 gives 3.766 source units. Its location brackets the change within one saved interval of 10,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

case900Template.TSensor (source units)

0

293.15

120000

284.8412

130000

288.6068

200000

285.1491

400000

283.1631

600000

280.6462

800000

282.8484

900000

280.1867

1000000

281.1016

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.