The recorded nor.dir channel spans 0 to 6.283 source units in this reference run. It starts at 0 and ends at 6.283. The first recorded maximum occurs at 3,600 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ZeroWindSpeed. The source file places it under Heat Transfer, Convection. We used the 101 stored values for nor.dir over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 5 recorded variables. Alongside the primary output there are nor.q_flow, wes.q_flow, sou.q_flow, eas.q_flow, nor.dir. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The primary channel spends 50.5% of its saved checkpoints at or above 3.142 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 3.142 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Zero wind speed. The simulated nor.dir channel runs from 0 to 6.283 source units over 3,600 seconds.
Zero wind speed. The simulated nor.dir channel runs from 0 to 6.283 source units over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 1,188 to 1,224 seconds. Subtracting 2.073 from 2.136 gives 0.06283 source units. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

nor.dir (source units)

0

0

720

1.256636

1188

2.073449

1224

2.136281

1440

2.513272

2160

3.769908

2880

5.026544

3600

6.28318

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.