The recorded pvtCol.m_flow channel spans -0.0498 to 0.0498 kg/s in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 21,600 seconds and the first minimum at 64,800 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named WISC. The source file places it under Fluid, photovoltaic-thermal Collectors. We used the 101 stored values for pvtCol.m_flow over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name weaDat (Reader TMY3), sin (Boundary p T), TOut (Temperature Two Port), TIn (Temperature Two Port). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel pvtCol.vol[3].T starts at 293.15, ends at 281.173 and has a recorded range of 281.173 to 306.803 K. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Wisc (wind and infrared sensitive collector) - uncovered photovoltaic-thermal. The simulated pvtCol.m_flow channel runs from -0.0498 to 0.0498 kg/s over 86,400 seconds.
Wisc (wind and infrared sensitive collector) - uncovered photovoltaic-thermal. The simulated pvtCol.m_flow channel runs from -0.0498 to 0.0498 kg/s over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 86,400 seconds gives a net 0 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

pvtCol.m_flow (kg/s)

pvtCol.vol[3].T (K)

0

0

293.15

17280

0.03818024

281.7732

21600

0.0498

282.0531

28512

0.0124789

282.3297

29376

-0.01763041

282.7623

34560

-0.04856602

298.3209

51840

0.04856602

287.7659

64800

-0.0498

289.4755

69120

-0.03818024

289.0846

86400

0

281.1726

What to check on site

Keep voltage, current, real power and energy distinct. Establish the reference direction at the measurement terminal before interpreting a sign change as import or export. Compare the same load boundary and duration in site data and the simulation.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.