The archived response ranges from 39,611 to 240,316. The median is 89,268 and the central half of the measurements extends from 65,729 to 120,760. Those figures use all 35 numeric observations in this source series and retain its original measurement scale.
What was measured
The CASTILL8 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as fatigue life of wire. It preserves the source scale and its sign. The file contains 1 numeric field per accepted row.
Spread across the original readings
The tenth percentile is 47,594 and the ninetieth is 147,625. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 200,705. This is the range of this sample, rather than a guaranteed operating envelope.

One row you can check
To check a real observation, take numeric row 18 after the header. Its response is 89,268. The overall arithmetic mean is 98,682, so this observation is -9,414 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 55,031, calculated by subtracting 65,729 from 120,760.
The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.
Worked data
Percentile | Observed response (source scale) | Number of numeric rows |
|---|---|---|
0 | 39611 | 35 |
10 | 47594.4 | 35 |
25 | 65729 | 35 |
50 | 89268 | 35 |
75 | 120760 | 35 |
90 | 147625.2 | 35 |
100 | 240316 | 35 |
Implications for an industrial comparison
Compare the specimen geometry, preparation, loading direction, conditioning and endpoint before using this distribution in a materials decision. Failure observations from a controlled test do not directly provide a field failure probability. A comparison with current production also needs the number of specimens withdrawn before the stated endpoint.
Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.
Source file and worked data
The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.
Cover photograph by Mikhail Nilov, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.