The published sen.I signal spans -14.88 to 0 A in the reference run. It starts at 0 and finishes at 0. The signed change between those endpoint samples is 0 A.

What the reference test measures

The Buildings model named WindTurbine comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 172,800 seconds. Industry Applied extracted 101 checkpoints for sen.I and kept the original signed values. The regular output spacing is 1,728 seconds. The solver may take different internal steps.

The model definition identifies sen (Generalized Sensor), res (Resistor), sou (Constant Voltage). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.

Settings to preserve when repeating the experiment

The published test declares res.R = 0.5, sou.V = 12, lin.R = 0.05. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.

Reading the two channels

The companion channel tur.vWin spans 1e-06 to 6.228 m/s across its 101 stored values. The primary trace first reaches its recorded maximum at 0 seconds and its minimum at 117,504 seconds. A time-aligned comparison preserves the meaning and units of each channel.

Wind-turbine DC output current. In the simulated WindTurbine case, sen.I ranges from -14.88 to 0 A over 172,800 seconds.
Wind-turbine DC output current. In the simulated WindTurbine case, sen.I ranges from -14.88 to 0 A over 172,800 seconds. Figure by Industry Applied.

Reproducing the largest recorded change

Between the stored points at 114,048 and 115,776 seconds, sen.I changes from -6.915 to -11.753. Subtracting the earlier reading gives -4.838 A. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.

The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.

Worked data

Simulation time (s)

sen.I (A)

tur.vWin (m/s)

0

0

1e-06

43200

0

1.5

86400

0

2.6

114048

-6.91521

5.20747

115776

-11.75339

5.889575

117504

-14.88036

6.228289

129600

-2.474487

4.1

172800

0

1e-06

Applying the result to an operating site

The current trend depends on the electrical operating point as well as wind speed. Air density, rotor control and conversion losses matter in field estimates. Use a power curve and time-resolved wind measurements before forecasting site energy.

For a local engineering comparison, write the measurement boundary, operating duty and instruments into the test record. Select comparable load or weather periods, then compare the measured trace with the simulated quantities. Establish a local acceptance tolerance using the intended duty and measurement uncertainty.

Model and data sources

Model definition. Original numerical reference series. Simulation and plotting script. Source project. Download the worked checkpoints as CSV.