The recorded winDir.y channel spans 0 to 6.283 source units in this reference run. It starts at 0 and ends at 6.283. The first recorded maximum occurs at 86,400 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Outside_CpData_Specification. The source file places it under Fluid, Sources. We used the 101 stored values for winDir.y over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name nor (Outside Cp Data), winDir (Ramp). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel nor.pWin starts at 1, ends at 1 and has a recorded range of 0.1855 to 1.004 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Wind pressure profile. The simulated winDir.y channel runs from 0 to 6.283 source units over 86,400 seconds.
Wind pressure profile. The simulated winDir.y channel runs from 0 to 6.283 source units over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 54,432 to 55,296 seconds. Subtracting 3.958 from 4.021 gives 0.06283 source units. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

winDir.y (source units)

nor.pWin (source units)

0

0

1.00001

17280

1.256637

0.3064009

34560

2.513274

0.3344011

51840

3.769911

0.5829367

54432

3.958407

0.6033241

55296

4.021239

0.6098981

69120

5.026548

0.7232051

86400

6.283185

1.00001

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.