The recorded Cp channel spans -0.6666 to 0.6 source units in this reference run. It starts at 0.6 and ends at 0.6. The first recorded maximum occurs at -2 seconds and the first minimum at -1.32 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named WindPressureLowRise. The source file places it under Airflow, Multizone. We used the 101 stored values for Cp over the interval -2 to 2 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name incAng (Angle), Cp (Real). The source declares Cp0 = 0.6. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 36.6% of its saved checkpoints at or above -0.03332 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is -0.1308 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Wind pressure function. The simulated Cp channel runs from -0.6666 to 0.6 source units over 4 seconds.
Wind pressure function. The simulated Cp channel runs from -0.6666 to 0.6 source units over 4 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from -1.8 to -1.76 seconds. Subtracting -0.1727 from -0.4552 gives -0.2825 source units. Its location brackets the change within one saved interval of 0.04 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

Cp (source units)

-2

0.6

-1.8

-0.1727225

-1.76

-0.4551806

-1.32

-0.6666385

-1.2

-0.1727225

-0.4

-0.3977162

0.4

-0.3977162

1.2

-0.1727225

2

0.6

What to check on site

Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.