Divide the mean of the lowest quarter of catch-can depths by the overall mean of 12 mm. In the worked example, Low-quarter mean collected depth of 9 mm gives low-quarter distribution uniformity of 75 %.

Set up the field measurement

Sort the observations first. A small low cluster behind one obstruction suggests a different repair from consistently low catches along an entire lateral. Keep the reference observation alongside the calculation, with the instrument identification, observation period and units. This makes it possible for the next shift to distinguish a new operating condition from a change in how the observation was recorded.

Two operating points

At 8 mm the calculated low-quarter distribution uniformity is 66.667 %. At 9 mm it is 75 %. Subtracting the first output from the second gives 8.3333 %. These values give two independent checkpoints for a spreadsheet or a logger conversion.

Low-quarter distribution uniformity (%) plotted against low-quarter mean collected depth (mm). Across the example the output changes from 33.333 to 100.
Low-quarter distribution uniformity (%) plotted against low-quarter mean collected depth (mm). Across the example the output changes from 33.333 to 100. Figure by Industry Applied.

Worked data

Low-quarter mean collected depth (mm)

Low-quarter distribution uniformity (%)

4

33.33333

6

50

8

66.66667

9

75

10

83.33333

12

100

Checking the working range

At the two ends of the example, an input of 4 gives 33.333 and an input of 12 gives 100. Use a value near each end to check your implementation. Testing only the middle row can conceal an incorrect offset, an inverted ratio or a unit conversion applied twice.

Interpreting the result

Keep can spacing representative of equal areas. A densely sampled corner can dominate an unweighted quarter. If measured performance sits outside the worked range, first repeat the comparison using field inputs and the same boundary. Preserve the original reading in the export. A discrepancy is easier to investigate when the field observation and the calculated output occupy separate columns.

Source and calculation data

For the underlying measurement context, see FAO’s technical handbook on pressurised irrigation. The operating values and sensitivity analysis here are an Industry Applied worked example. Download the input and output values to verify the calculation with the values from your own site.