The hex.sta_b1.T trace covers 13.101 to 21.952 °C, a temperature span of 8.851 K. The first recorded maximum occurs at 3,276 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named WetCoilDiscretizedPControl. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for hex.sta_b1.T over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name con (Lim PID), mot (Ideal Motor). The source declares m1_flow_nominal = 5. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel hex.sta_a1.T covers 278.15 to 288.15 K. At 2,700 s, the primary value is 295.06 and the companion is 278.15. Their signed difference is 16.91 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Wet coil discretized p control. The simulated hex.sta_b1.T channel runs from 286.251 to 295.102 K over 3,600 seconds.
Wet coil discretized p control. The simulated hex.sta_b1.T channel runs from 286.251 to 295.102 K over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 72 to 108 seconds. Subtracting 292.463 from 290.727 gives -1.736 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hex.sta_b1.T (K)

hex.sta_a1.T (K)

0

293.15

278.15

72

292.4633

278.15

108

290.7271

278.15

720

289.9608

278.15

864

286.251

278.15

1440

286.4286

278.15

2160

290.263

278.15

2880

294.9965

278.15

3276

295.1021

288.15

3600

295.0469

288.15

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.