The recorded solTim.locTim channel spans -1,831 to 862,169 source units in this reference run. It starts at -1,831 and ends at 862,169. The first recorded maximum occurs at 864,000 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SolarTime. The source file places it under Boundary Conditions, Weather Data. We used the 101 stored values for solTim.locTim over the interval 0 to 864,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name modTim (Model Time), locTim (Local Civil Time), solTim (Solar Time), eqnTim (Equation Of Time). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel solTim.solTim covers -2,047 to 861,701 source units. At 864,000 s, the primary value is 862,169 and the companion is 861,701. Their signed difference is 468.75 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Weather data solar time. The simulated solTim.locTim channel runs from -1,831 to 862,169 source units over 864,000 seconds.
Weather data solar time. The simulated solTim.locTim channel runs from -1,831 to 862,169 source units over 864,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 259,200 to 267,840 seconds. Subtracting 257,369 from 266,009 gives 8,640 source units. Its location brackets the change within one saved interval of 8,640 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

solTim.locTim (source units)

solTim.solTim (source units)

0

-1830.667

-2047.079

172800

170969.3

170699.6

259200

257369.3

257073.4

267840

266009.3

265710.8

345600

343769.3

343447.5

518400

516569.3

516196.8

691200

689369.3

688947.8

864000

862169.3

861700.6

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.