The recorded chePre.PIn channel spans 96,600 to 101,700 source units in this reference run. It starts at 99,500 and ends at 99,900. The first recorded maximum occurs at 604,800 seconds and the first minimum at 4,665,600 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named CheckPressure. The source file places it under Boundary Conditions, Weather Data. We used the 101 stored values for chePre.PIn over the interval 0 to 8,640,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name chePre (Check Pressure), modTim (Model Time), conTim (Convert Time), datRea (Combi Table1 Ds). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 55.4% of its saved checkpoints at or above 99,150 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 99,257 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Weather data pressure check. The simulated chePre.PIn channel runs from 96,600 to 101,700 source units over 8,640,000 seconds.
Weather data pressure check. The simulated chePre.PIn channel runs from 96,600 to 101,700 source units over 8,640,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 5,443,200 to 5,529,600 seconds. Subtracting 98,400 from 101,000 gives 2,600 source units. Its location brackets the change within one saved interval of 86,400 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

chePre.PIn (source units)

0

99500

604800

101700

1728000

99000

3456000

99500

4665600

96600

5184000

99100

5443200

98400

5529600

101000

6912000

99600

8640000

99900

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.