The recorded TEng.y channel spans 273.15 to 473.15 source units in this reference run. It starts at 273.15 and ends at 473.15. The first recorded maximum occurs at 360 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named WarmUpTemperature. The source file places it under Fluid, CH Ps. We used the 101 stored values for TEng.y over the interval 0 to 900 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name TEng (Ramp), runSig (Boolean Table), actMod (Mode), transition1 (Transition With Signal). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel transition1.condition starts at 1, ends at 0 and has a recorded range of 0 to 1 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Warm-up temperature. The simulated TEng.y channel runs from 273.15 to 473.15 source units over 900 seconds.
Warm-up temperature. The simulated TEng.y channel runs from 273.15 to 473.15 source units over 900 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 9 seconds. Subtracting 273.15 from 278.15 gives 5 source units. Its location brackets the change within one saved interval of 9 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TEng.y (source units)

transition1.condition (source units)

0

273.15

1

9

278.15

1

180

373.15

1

360

473.15

1

540

473.15

1

720

473.15

0

900

473.15

0

What to check on site

Compare fuel or electrical input with useful heat at a declared delivery boundary. Include the warm-up interval and any period on standby. Separate a temperature setpoint from the measured outlet and keep auxiliary energy in a stated part of the balance.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.