The U_EN673 trace ranges from 0.99238 to 0.99581 across 101 saved checkpoints. It begins at 0.99581 and finishes at 0.99238 after 1,000,000 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

The largest change in U_EN673 between saved samples lies between simulation times 0 s and 10,000 s. The channel moves from 0.99581 to 0.99509 across that interval. A finer export is needed to resolve what happens between those observations.

The component declarations name windowEN673 (Window), boundaryWall (Boundary Wall), boundaryWall1 (Boundary Wall), boundaryWall2 (Boundary Wall). The source declares TZone = 273.15 + 20, TOut = 273.15, TDryBulFixed = 293.15. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. U_EN673 begins at 0.99581 and ends at 0.99238. U_default begins at 0.97209 and ends at 0.96981. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 10,000 seconds. Subtracting 0.9958 from 0.9951 gives -0.000718 source units. Its location brackets the change within one saved interval of 10,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

U_EN673 (source units)

U_default (source units)

0

0.9958091

0.972093

10000

0.995091

0.9598489

200000

0.9927621

0.9358776

400000

0.99244

0.9549941

600000

0.992396

0.97004

800000

0.9923936

0.9472098

1000000

0.992379

0.9698147

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Checking the two recorded channels

At 10,000 s, U_EN673 reads 0.99509 and U_default reads 0.95985. Across the run, the second channel ranges from 0.91386 to 0.98167. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.