The roo.yCFD[2] trace ranges from 0.0013135 to 0.019333 across 101 saved checkpoints. It begins at 0.0013135 and finishes at 0.0040251 after 120 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ForcedConvection. The source file places it under Thermal Zones, Detailed, FFD. We used the 101 stored values for roo.yCFD[2] over the interval 0 to 120 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 1 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The primary channel spends 54.5% of its saved checkpoints at or above 0.01032 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 0.0112 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Ventilation with forced convection in an empty room. The simulated roo.yCFD[2] channel runs from 0.001313 to 0.01933 source units over 120 seconds.
Ventilation with forced convection in an empty room. The simulated roo.yCFD[2] channel runs from 0.001313 to 0.01933 source units over 120 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 6 to 7.2 seconds. Subtracting 0.001313 from 0.006319 gives 0.005005 source units. Its location brackets the change within one saved interval of 1.2 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

roo.yCFD[2] (source units)

0

0.001313477

6

0.001313477

7.2

0.006318661

24

0.01127552

43.2

0.01933252

48

0.01933252

72

0.01364985

96

0.00816985

120

0.004025063

What to check on site

Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.