The recorded structure.TSensor[1] channel spans 279.41 to 293.15 source units in this reference run. It starts at 293.15 and ends at 279.41. The first recorded maximum occurs at 0 seconds and the first minimum at 2,000,000 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named ConstantAirFlowRecup. The source file places it under Templates. We used the 101 stored values for structure.TSensor[1] over the interval 0 to 2,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 5 recorded variables. Alongside the primary output there are structure.TSensor[1], structure.TSensor[2], structure.TSensor[3], constantAirFlowRecup.hex.T_in1, constantAirFlowRecup.hex.T_in2. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel structure.TSensor[2] covers 279.087 to 293.15 source units. At 2,000,000 s, the primary value is 279.41 and the companion is 279.087. Their signed difference is 0.3225 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Ventilation system. The simulated structure.TSensor[1] channel runs from 279.41 to 293.15 source units over 2,000,000 seconds.
Ventilation system. The simulated structure.TSensor[1] channel runs from 279.41 to 293.15 source units over 2,000,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 20,000 seconds. Subtracting 293.15 from 291.94 gives -1.21 source units. Its location brackets the change within one saved interval of 20,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

structure.TSensor[1] (source units)

structure.TSensor[2] (source units)

0

293.15

293.15

20000

291.9404

291.923

400000

287.1605

287.2377

800000

284.0966

283.9773

1200000

282.8701

282.6874

1600000

281.6958

281.5727

2000000

279.4099

279.0874

What to check on site

Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.