The cap.T trace covers 13.655 to 30.034 °C, a temperature span of 16.379 K. The first recorded maximum occurs at 96,768 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named OperationModes. The source file places it under variable air volume Reheat, Controls. We used the 101 stored values for cap.T over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name TCoiHea (Constant), mode (Integer Pass Through), TOut (Constant), occSch (Occupancy Schedule). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel mode.y starts at 2, ends at 2 and has a recorded range of 1 to 3 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

VAV reheat operation modes. The simulated cap.T channel runs from 286.805 to 303.184 K over 172,800 seconds.
VAV reheat operation modes. The simulated cap.T channel runs from 286.805 to 303.184 K over 172,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 162,432 to 164,160 seconds. Subtracting 286.805 from 299.561 gives 12.756 K. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

cap.T (K)

mode.y (source units)

0

293.15

2

34560

293.15

1

69120

292.4428

2

96768

303.1843

2

103680

294.4079

2

138240

293.15

1

162432

286.8053

2

164160

299.5615

3

172800

293.4015

2

What to check on site

Compare fuel or electrical input with useful heat at a declared delivery boundary. Include the warm-up interval and any period on standby. Separate a temperature setpoint from the measured outlet and keep auxiliary energy in a stated part of the balance.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.