The conEco.TOut trace covers 12 to 24 °C, a temperature span of 12 K. The first recorded maximum occurs at 453,600 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ControllerEconomizer. The source file places it under Air, Systems, Single Zone, variable air volume. We used the 101 stored values for conEco.TOut over the interval 0 to 604,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name conEco (Controller Economizer), mixAirTem (Sine), retAirTem (Sine), mixAirTemSet (Sine). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel conEco.TMix covers 285.65 to 300.65 K. At 453,600 s, the primary value is 297.15 and the companion is 300.65. Their signed difference is -3.5 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

VAV controller economiser. The simulated conEco.TOut channel runs from 285.15 to 297.15 K over 604,800 seconds.
VAV controller economiser. The simulated conEco.TOut channel runs from 285.15 to 297.15 K over 604,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 127,008 to 133,056 seconds. Subtracting 292.274 from 289.658 gives -2.616 K. Its location brackets the change within one saved interval of 6,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

conEco.TOut (K)

conEco.TMix (K)

0

291.15

293.15

120960

294.6767

297.5584

127008

292.2743

294.5554

133056

289.6579

291.2848

151200

285.15

285.65

241920

285.4437

286.0171

362880

296.8564

300.2829

453600

297.15

300.65

483840

287.6233

288.7416

604800

291.15

293.15

What to check on site

Separate a calculated setpoint from the damper or fan command and from the measured service delivered. Trend the active operating mode, request, actual flow and zone condition on one clock. A sequence can change state correctly while the terminal fails to reach duty.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.