The saved conChaWid.y signal is high at 82 of 101 checkpoints and changes state between adjacent checkpoints 5 times. The first recorded change is from 0 at 288 s to 1 at 324 s.
What the reference test measures
The Buildings model named VariablePulse comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 3,600 seconds. Industry Applied extracted 101 checkpoints for conChaWid.y and kept the original signed values. The regular output spacing is 36 seconds. The solver may take different internal steps.
The model definition identifies conChaWid (Variable Pulse), conTru (Variable Pulse), fal (Variable Pulse). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.
Settings to preserve when repeating the experiment
The published test declares conTru.period = 900, fal.period = 900, truFal.period = 900. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.
Reading the two channels
At 324 seconds, conChaWid.y is 1 and conChaWid.u is 0.021. Subtracting the second channel from the first gives +0.979 encoded state, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.

Reproducing the largest recorded change
Between the stored points at 288 and 324 seconds, conChaWid.y changes from 0 to 1. Subtracting the earlier reading gives +1 encoded state. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.
State changes are bracketed by saved output times. Counting high samples is not a pulse-width measurement. A brief transition between output points can be invisible in the saved Boolean trace.
Worked data
Simulation time (s) | conChaWid.y (state) | conChaWid.u (state) |
|---|---|---|
0 | 0 | 0 |
288 | 0 | 0 |
324 | 1 | 0.02133333 |
900 | 1 | 0.5333334 |
1800 | 1 | 0.8 |
2700 | 1 | 0.8 |
3600 | 1 | 0.8 |
Applying the result to an operating site
A pulse-width command controls how long the output stays in a state. Total changes and time in the active state can move independently. Verify whether the receiving logger captures edges or polls a level.
For an Australian monitoring project, write the intended sample interval, timestamp convention, tag units and missed-update policy into the acceptance record. Re-run this comparison on the installed signal path and retain the raw export so a later dashboard change can be checked against the same baseline.