The varSpeDX.vol.T trace covers 15.033 to 20.125 °C, a temperature span of 5.092 K. The first recorded maximum occurs at 936 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named VariableSpeed. The source file places it under Fluid, direct expansion Systems, Cooling, Air Source. We used the 101 stored values for varSpeDX.vol.T over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name varSpeDX (Variable Speed), sin (Boundary p T), sou (Boundary p T), TEvaIn (Ramp). The source declares dp_nominal = 1000. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel TEvaIn.y starts at 293.15, ends at 298.15 and has a recorded range of 293.15 to 298.15 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Variable-speed direct expansion coil. The simulated varSpeDX.vol.T channel runs from 288.183 to 293.275 K over 3,600 seconds.
Variable-speed direct expansion coil. The simulated varSpeDX.vol.T channel runs from 288.183 to 293.275 K over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 936 to 972 seconds. Subtracting 293.275 from 291.348 gives -1.927 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

varSpeDX.vol.T (K)

TEvaIn.y (source units)

0

292.55

293.15

720

293.15

293.15

936

293.2749

293.45

972

291.3483

293.75

1440

288.4548

297.65

1872

288.1826

298.15

2160

288.3449

298.15

2880

288.5602

298.15

3600

288.5591

298.15

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.