The recorded fan32.dp channel spans -136.919 to 0 Pa in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 0 seconds and the first minimum at 139,968 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named VAVSystemCTControl. The source file places it under VAVCO2. We used the 101 stored values for fan32.dp over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name mixBox (Mixing Box), conSupFan (Lim PID), onSig (Boolean Pulse), dp32 (Gain). The source declares scaM_flow = 1, scaDpFanSup_nominal = 1, scaDpFanRet_nominal = 1. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel fan56.dp covers -54.768 to 0 Pa. At 139,968 s, the primary value is -136.919 and the companion is -54.768. Their signed difference is -82.152 Pa, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Variable air volume system ct control. The simulated fan32.dp channel runs from -136.919 to 0 Pa over 172,800 seconds.
Variable air volume system ct control. The simulated fan32.dp channel runs from -136.919 to 0 Pa over 172,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 150,336 to 152,064 seconds. Subtracting -117.994 from 0 gives 117.994 Pa. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

fan32.dp (Pa)

fan56.dp (Pa)

0

0

0

34560

-82.18515

-32.87406

69120

0

0

103680

0

0

138240

-136.892

-54.75681

139968

-136.9194

-54.76776

150336

-117.9939

-47.19755

152064

0

0

172800

0

0

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.