The recorded flo.cor.air.vol.T temperature spans 18.262 °C to 20.136 °C in this simulation. That is a change of 1.8742 K. The first saved maximum occurs at 69,120 s. The source trace and download retain absolute temperatures in kelvin.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named ASHRAE2006. The source file places it under variable air volume Reheat. We used the 101 stored values for flo.cor.air.vol.T over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 25 recorded variables. Alongside the primary output there are flo.sou.air.vol.T, flo.eas.air.vol.T, flo.nor.air.vol.T, flo.wes.air.vol.T, flo.cor.air.vol.T. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
At 19,008 s, flo.cor.air.vol.T is 292.436 K and flo.sou.air.vol.T is 291.485 K. Subtracting the second value from the first gives 0.95142 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 105,408 to 107,136 seconds. Subtracting 292.677 from 291.439 gives -1.238 K. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | flo.cor.air.vol.T (K) | flo.sou.air.vol.T (K) |
|---|---|---|
0 | 293.15 | 293.15 |
20736 | 291.4121 | 290.6425 |
34560 | 293.1521 | 293.2234 |
69120 | 293.2863 | 293.1551 |
103680 | 292.7 | 291.8215 |
105408 | 292.6766 | 291.7978 |
107136 | 291.4385 | 290.9181 |
138240 | 293.1646 | 293.1472 |
172800 | 292.9554 | 292.267 |
What to check on site
Compare fuel or electrical input with useful heat at a declared delivery boundary. Include the warm-up interval and any period on standby. Separate a temperature setpoint from the measured outlet and keep auxiliary energy in a stated part of the balance.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.