The recorded EFan.y channel spans 0 to 5,964,749 source units in this reference run. It starts at 0 and ends at 5,964,749. The first recorded maximum occurs at 499,752 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ChillerDXHeatingEconomizer. The source file places it under Air, Systems, Single Zone, variable air volume. We used the 101 stored values for EFan.y over the interval 0 to 504,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name con (Controller Chiller direct expansion Heating Economizer), occSch (Occupancy Schedule). The source declares TSupChi_nominal = 279.15. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. EFan.y begins at 0 and ends at 5.9647e+06. EHea.y begins at 0 and ends at 9.2482e+08. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Variable air volume flow system with single themal zone and conventional control. The simulated EFan.y channel runs from 0 to 5,964,749 source units over 504,800 seconds.
Variable air volume flow system with single themal zone and conventional control. The simulated EFan.y channel runs from 0 to 5,964,749 source units over 504,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 474,512 to 479,560 seconds. Subtracting 3,700,131 from 4,636,918 gives 936,787 source units. Its location brackets the change within one saved interval of 5,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

EFan.y (source units)

EHea.y (source units)

0

0

0

100960

1539159

8.48411e+07

201920

1626834

4.240348e+08

302880

1722754

6.988924e+08

403840

3257010

8.520615e+08

474512

3700131

9.248207e+08

479560

4636918

9.248207e+08

499752

5964749

9.248207e+08

504800

5964749

9.248207e+08

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.