The published triggeredSampler.y signal spans 0 to 16 source signal units in the reference run. It starts at 0 and finishes at 16. The signed change between those endpoint samples is +16 source signal units.

What the reference test measures

The Buildings model named Edge comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 5 seconds. Industry Applied extracted 101 checkpoints for triggeredSampler.y and kept the original signed values. The regular output spacing is 0.05 seconds. The solver may take different internal steps.

The model definition identifies triggeredSampler (Triggered Sampler), booPul (Pulse), edge1 (Edge). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.

Settings to preserve when repeating the experiment

The published test declares booPul.width = 0.5, booPul.period = 1.0, ramp2.duration = 5. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.

Reading the two channels

At 1 seconds, triggeredSampler.y is 0 and triggeredSampler.u is 4. Subtracting the second channel from the first gives -4 source signal units, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.

Value captured on a rising edge. In the simulated Edge case, triggeredSampler.y ranges from 0 to 16 source signal units over 5 seconds.
Value captured on a rising edge. In the simulated Edge case, triggeredSampler.y ranges from 0 to 16 source signal units over 5 seconds. Figure by Industry Applied.

Reproducing the largest recorded change

Between the stored points at 1 and 1.05 seconds, triggeredSampler.y changes from 0 to 4. Subtracting the earlier reading gives +4 source signal units. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.

The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.

Worked data

Simulation time (s)

triggeredSampler.y (signal units)

triggeredSampler.u (signal units)

0

0

0

1

0

4

1.05

4

4.2

1.25

4

5

2.5

8

10

3.75

12

15

4.05

16

16.2

5

16

20

Applying the result to an operating site

A short event pulse may disappear between trend samples even though it triggered a capture. Recording the value captured by the event provides another line of evidence. Keep the edge timestamp with that retained value.

For an Australian monitoring project, write the intended sample interval, timestamp convention, tag units and missed-update policy into the acceptance record. Re-run this comparison on the installed signal path and retain the raw export so a later dashboard change can be checked against the same baseline.