The recorded adsolair58.com.P channel spans 0 to 6,429 W in this reference run. It starts at 0 and ends at 6,429. The first recorded maximum occurs at 2,820 seconds and the first minimum at 0 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named AdsolairDatasheetSummer. The source file places it under Airflow, air handler. We used the 101 stored values for adsolair58.com.P over the interval 0 to 3,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name phi_evap (Phi p TX). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel adsolair58.fanBot.P covers 3,269 to 4,734 W. At 120 s, the primary value is 0 and the companion is 4,734. Their signed difference is -4,734 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Validaiton using nominal data sheet performance data for summer. The simulated adsolair58.com.P channel runs from 0 to 6,429 W over 3,000 seconds.
Validaiton using nominal data sheet performance data for summer. The simulated adsolair58.com.P channel runs from 0 to 6,429 W over 3,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed adsolair58.com.P samples by the trapezoidal rule gives 4.446 kWh over 3,000 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

adsolair58.com.P (W)

adsolair58.fanBot.P (W)

0

0

3500.935

270

0

4734.136

300

2933.65

4734.136

600

4288.333

4734.136

1200

6387.882

4734.136

1800

6428.363

4734.136

2400

6428.849

4734.136

2820

6428.855

4734.136

3000

6428.855

4734.136

What to check on site

Separate a calculated setpoint from the damper or fan command and from the measured service delivered. Trend the active operating mode, request, actual flow and zone condition on one clock. A sequence can change state correctly while the terminal fails to reach duty.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.