The archived response ranges from 11.8 to 12.4. The median is 12.1 and the central half of the measurements extends from 12 to 12.2. Those figures use all 10 numeric observations in this source series and retain its original measurement scale.

What was measured

The NATR45 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as cutoff bias of vacuum tubes. It preserves the source scale and its sign. The file contains 1 numeric field per accepted row.

Spread across the original readings

The tenth percentile is 11.89 and the ninetieth is 12.31. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 0.6. This is the range of this sample, rather than a guaranteed operating envelope.

Vacuum tube cutoff bias. The 25th, 50th and 75th percentiles of the measurements are 12, 12.1 and 12.2.
Vacuum tube cutoff bias. The 25th, 50th and 75th percentiles of the measurements are 12, 12.1 and 12.2. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 1 after the header. Its response is 12.1. The overall arithmetic mean is 12.1, so this observation is 0 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 0.2, calculated by subtracting 12 from 12.2.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

Percentile

Observed response (source scale)

Number of numeric rows

0

11.8

10

10

11.89

10

25

12

10

50

12.1

10

75

12.2

10

90

12.31

10

100

12.4

10

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.