The recorded solCol.m_flow channel spans -0.2197 to 0.2197 kg/s in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 21,600 seconds and the first minimum at 64,800 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Tubular. The source file places it under Fluid, Solar Collectors. We used the 101 stored values for solCol.m_flow over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name solCol (ASHRAE93), weaDat (Reader TMY3), sin (Boundary p T), TOut (Temperature Two Port). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel solCol.vol[3].T starts at 293.15, ends at 282.93 and has a recorded range of 282.93 to 321.842 K. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Use of tubular. The simulated solCol.m_flow channel runs from -0.2197 to 0.2197 kg/s over 86,400 seconds.
Use of tubular. The simulated solCol.m_flow channel runs from -0.2197 to 0.2197 kg/s over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 86,400 seconds gives a net 0 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

solCol.m_flow (kg/s)

solCol.vol[3].T (K)

0

0

293.15

17280

0.1684631

283.0266

21600

0.2197331

283.0503

28512

0.05490905

285.2099

29376

-0.07779086

292.9469

34560

-0.2142884

301.5572

51840

0.2142884

287.9084

64800

-0.2197331

292.7865

69120

-0.1684631

292.6674

86400

0

282.9297

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.