The recorded indTanHex.vol[1].T temperature spans 20 °C to 41.406 °C in this simulation. That is a change of 21.406 K. The first saved maximum occurs at 15 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named IndirectTankHeatExchanger. The source file places it under Fluid, Storage. We used the 101 stored values for indTanHex.vol[1].T over the interval 0 to 15 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name indTanHex (Indirect Tank Heat Exchanger). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 2.55 s, indTanHex.vol[1].T is 301.007 K and indTanHex.vol[2].T is 308.37 K. Subtracting the second value from the first gives -7.3625 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Use of indirect tank heat exchanger. The simulated indTanHex.vol[1].T channel runs from 293.15 to 314.556 K over 15 seconds.
Use of indirect tank heat exchanger. The simulated indTanHex.vol[1].T channel runs from 293.15 to 314.556 K over 15 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 2.25 to 2.4 seconds. Subtracting 299.515 from 300.262 gives 0.7464 K. Its location brackets the change within one saved interval of 0.15 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

indTanHex.vol[1].T (K)

indTanHex.vol[2].T (K)

0

293.15

293.15

2.25

299.5153

306.7339

2.4

300.2617

307.5785

3

303.1878

310.4331

6

312.1464

316.1635

9

314.2018

316.9214

12

314.5161

317.0027

15

314.5562

317.0106

What to check on site

Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.