The test drives criSol.TIn across the numerical values 20 to 40. The model declares kelvin for this connector and applies synthetic inputs over that range. These are software test values. A field temperature requires a physically representative input and an independently checked sensor scale.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named GCritCalc. The source file places it under Fluid, Solar Collectors, Controls. We used the 101 stored values for criSol.TIn over the interval 0 to 100 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name criSol (G Crit Calc). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 27 s, criSol.TIn is 39.921 K and criSol.TEnv is 0.48943 K. Subtracting the second value from the first gives 39.432 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 1 seconds. Subtracting 30 from 30.628 gives 0.6279 K. Its location brackets the change within one saved interval of 1 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

criSol.TIn (K)

criSol.TEnv (K)

0

30

10

1

30.6279

15.87785

20

39.51057

10

25

40

10

40

35.87785

10

60

24.12215

10

75

20

10

80

20.48944

10

100

30

10

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, criSol.TEnv uses K. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.