The TVol.T trace covers 16 to 20.045 °C, a temperature span of 4.045 K. The first recorded maximum occurs at 51,840 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named HeatingRod. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for TVol.T over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name numSwiHR (Integer Output), Pel (Real Output). The source declares rhoWat = 1000. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel THeaOut.T covers 289.15 to 293.195 K. At 112,320 s, the primary value is 292.964 and the companion is 292.965. Their signed difference is -0.001556 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Usage of the heating rod. The simulated TVol.T channel runs from 289.15 to 293.195 K over 172,800 seconds.
Usage of the heating rod. The simulated TVol.T channel runs from 289.15 to 293.195 K over 172,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 31,104 to 32,832 seconds. Subtracting 290.569 from 290.984 gives 0.4153 K. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TVol.T (K)

THeaOut.T (K)

0

289.15

289.15

1728

289.1498

289.1501

31104

290.5686

290.57

32832

290.9839

290.9853

34560

291.3991

291.4005

51840

293.1949

293.1949

69120

293.1451

293.1453

103680

292.8315

292.8317

138240

293.191

293.191

172800

292.9869

292.9872

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.