The sigBus.TConInMea trace ranges from 283.15 to 343.15 across 101 saved checkpoints. It begins at 283.15 and finishes at 283.15 after 100 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named OperationalEnvelope. The source file places it under Fluid, Heat Pumps, Modular Reversible, Controls, Safety. We used the 101 stored values for sigBus.TConInMea over the interval 0 to 100 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name ySetPul (Constant), TConOutEmu (Trapezoid), TEvaInEmu (Pulse), hea (Boolean Step). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 28 s, sigBus.TConInMea reads 307.15 and yOut reads 1. Across the run, the second channel ranges from 0 to 1. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Usage of operational envelope. The simulated sigBus.TConInMea channel runs from 283.15 to 343.15 source units over 100 seconds.
Usage of operational envelope. The simulated sigBus.TConInMea channel runs from 283.15 to 343.15 source units over 100 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 27 to 28 seconds. Subtracting 319.15 from 307.15 gives -12 source units. Its location brackets the change within one saved interval of 1 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

sigBus.TConInMea (source units)

yOut (source units)

0

283.15

1

5

343.15

0

20

343.15

0

27

319.15

1

28

307.15

1

40

283.15

1

60

343.15

1

80

283.15

0

100

283.15

0

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.