The bufferStorage.layer[4].T trace covers 37.512 to 61.322 °C, a temperature span of 23.809 K. The first recorded maximum occurs at 86,400 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named StorageDetailedExample. The source file places it under Fluid, Storage. We used the 101 stored values for bufferStorage.layer[4].T over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 4 recorded variables. Alongside the primary output there are bufferStorage.heatingCoil1.Therm1[4].Q_flow, bufferStorage.layer[4].T, bufferStorage.portHC1In.p, bufferStorage.portHC1Out.p. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel bufferStorage.heatingCoil1.Therm1[4].Q_flow starts at 0, ends at 1,727 and has a recorded range of 0 to 1,727 W. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.
![Usage for storage detailed. The simulated bufferStorage.layer[4].T channel runs from 310.662 to 334.472 K over 86,400 seconds.](https://static.wixstatic.com/media/21e41b_982cdb8986b6419d9d3e77df5eb01171~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_982cdb8986b6419d9d3e77df5eb01171~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 864 seconds. Subtracting 318.15 from 312.137 gives -6.013 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | bufferStorage.layer[4].T (K) | bufferStorage.heatingCoil1.Therm1[4].Q_flow (W) |
|---|---|---|
0 | 318.15 | 0 |
864 | 312.1366 | 534.2202 |
2592 | 310.6624 | 532.2891 |
17280 | 333.9433 | 1722.38 |
34560 | 334.4367 | 1726.202 |
51840 | 334.4558 | 1726.876 |
69120 | 334.4659 | 1727.258 |
86400 | 334.4717 | 1727.477 |
What to check on site
Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.
![Usage for storage detailed. Range and median of consecutive groups of recorded samples. bufferStorage.layer[4].T (K). 3,456 to 83.8k.](/story-art/823aea4efd24cd500.webp)