The recorded upProCon.yChiWatMinFloSet channel spans 1 to 2 source units in this reference run. It starts at 1 and ends at 2. The first recorded maximum occurs at 760 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named UpWithoutOnOff. The source file places it under Controls, OBC, ASHRAE, G36, Plants, Chillers, Staging, Processes. We used the 101 stored values for upProCon.yChiWatMinFloSet over the interval 0 to 2,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name upProCon (Up), booPul (Pulse), staUp (Not), chiLoa (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel upProCon.yChiDem covers 1,500 to 2,000 source units. At 0 s, the primary value is 1 and the companion is 2,000. Their signed difference is -1,999 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Up without on off. The simulated upProCon.yChiWatMinFloSet channel runs from 1 to 2 source units over 2,000 seconds.
Up without on off. The simulated upProCon.yChiWatMinFloSet channel runs from 1 to 2 source units over 2,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 540 to 560 seconds. Subtracting 1.3 from 1.367 gives 0.06667 source units. Its location brackets the change within one saved interval of 20 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

upProCon.yChiWatMinFloSet (source units)

upProCon.yChiDem (source units)

0

1

2000

400

1

1500

540

1.3

1500

560

1.366667

1500

760

2

1500

800

2

1500

1200

2

2000

1600

2

2000

2000

2

2000

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.