The recorded hydraulicBus.TFwrdInMea channel spans 303.15 to 323.15 source units in this reference run. It starts at 303.15 and ends at 323.15. The first recorded maximum occurs at 376 seconds and the first minimum at 0 seconds.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named Pump. The source file places it under Systems, Hydraulic Modules. We used the 101 stored values for hydraulicBus.TFwrdInMea over the interval 0 to 800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name hydRes (Pressure Drop). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel hydraulicBus.TFwrdOutMea covers 302.992 to 323.162 source units. At 208 s, the primary value is 322.309 and the companion is 303.349. Their signed difference is 18.96 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Unmixed pump circuit. The simulated hydraulicBus.TFwrdInMea channel runs from 303.15 to 323.15 source units over 800 seconds.
Unmixed pump circuit. The simulated hydraulicBus.TFwrdInMea channel runs from 303.15 to 323.15 source units over 800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 184 to 192 seconds. Subtracting 319.107 from 320.707 gives 1.6 source units. Its location brackets the change within one saved interval of 8 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hydraulicBus.TFwrdInMea (source units)

hydraulicBus.TFwrdOutMea (source units)

0

303.15

303.15

160

317.4123

303.045

184

319.1074

302.9922

192

320.707

303.0421

320

323.1495

323.1203

376

323.15

323.1491

480

323.15

323.153

640

323.15

323.1593

800

323.15

323.162

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.