The outerWall.propsBus_a.surfRad.T trace covers 18.148 to 20 °C, a temperature span of 1.852 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named WallUnitTest. The source file places it under Buildings, Components. We used the 101 stored values for outerWall.propsBus_a.surfRad.T over the interval 0 to 1,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name boundaryWall (Boundary Wall), internalWall (Internal Wall), outerWall (Outer Wall), slabOnGround (Slab On Ground). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel boundaryWall.propsBus_a.surfRad.T covers 293.15 to 294.113 K. At 910,000 s, the primary value is 291.298 and the companion is 294.113. Their signed difference is -2.814 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Unit test for verifying results for all wall components. The simulated outerWall.propsBus_a.surfRad.T channel runs from 291.298 to 293.15 K over 1,000,000 seconds.
Unit test for verifying results for all wall components. The simulated outerWall.propsBus_a.surfRad.T channel runs from 291.298 to 293.15 K over 1,000,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 40,000 to 50,000 seconds. Subtracting 292.783 from 292.606 gives -0.177 K. Its location brackets the change within one saved interval of 10,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

outerWall.propsBus_a.surfRad.T (K)

boundaryWall.propsBus_a.surfRad.T (K)

0

293.15

293.15

40000

292.783

293.4367

50000

292.606

293.5391

200000

291.8093

294.0683

400000

291.4217

294.1115

600000

291.4716

294.1129

800000

291.6812

294.1129

910000

291.2985

294.113

1000000

291.4831

294.113

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.