The recorded monoLayerAir.port_a.Q_flow channel spans -644.893 to 644.893 W in this reference run. It starts at -644.893 and ends at 644.893. The first recorded maximum occurs at 86,400 seconds and the first minimum at 0 seconds.
The system being tested
The KU Leuven IDEAS project publishes the IDEAS test named MonoLayer. The source file places it under Buildings, Components, Conductive Heat Transfer. We used the 101 stored values for monoLayerAir.port_a.Q_flow over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name fixTem (Fixed Temperature), preTem (Prescribed Temperature), monoLayerSolid (Mono Layer), monoLayerAir (Mono Layer). The source declares A = 10. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel monoLayerSolid.port_a.Q_flow covers -2,860 to 650.389 W. At 0 s, the primary value is -644.893 and the companion is -2,860. Their signed difference is 2,215 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
Integrating the signed monoLayerAir.port_a.Q_flow samples by the trapezoidal rule gives 0 kWh over 86,400 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | monoLayerAir.port_a.Q_flow (W) | monoLayerSolid.port_a.Q_flow (W) |
|---|---|---|
0 | -644.8926 | -2860 |
864 | -630.6445 | -2470.977 |
17280 | -368.0149 | -451.3008 |
34560 | -114.1474 | 86.62914 |
51840 | 114.1474 | 347.1744 |
69120 | 368.0149 | 514.8163 |
86400 | 644.8926 | 650.3895 |
What to check on site
Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.