The recorded humRat.X_w channel spans 0.01313 to 0.1667 source units in this reference run. It starts at 0.1667 and ends at 0.01313. The first recorded maximum occurs at 0 seconds and the first minimum at 1 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named HumidityRatioPressure. The source file places it under Utilities, Psychrometrics. We used the 101 stored values for humRat.X_w over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name vapPre (p W X), XHumDryAir (Ramp), p (Constant), assertEquality (Assert Equality). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel humRat.p_w covers 2,121 to 24,654 source units. At 0 s, the primary value is 0.1667 and the companion is 24,654. Their signed difference is -24,654 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Unit test for humidity ratio. The simulated humRat.X_w channel runs from 0.01313 to 0.1667 source units over 1 seconds.
Unit test for humidity ratio. The simulated humRat.X_w channel runs from 0.01313 to 0.1667 source units over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.99 to 1 seconds. Subtracting 0.01494 from 0.01313 gives -0.001815 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

humRat.X_w (source units)

humRat.p_w (source units)

0

0.1666667

24653.88

0.2

0.1399033

21005.21

0.4

0.1113639

16991.9

0.6

0.08086546

12556.44

0.8

0.04819919

7628.525

0.99

0.0149404

2411.997

1

0.01312543

2121.305

What to check on site

Record the physical quantity and its reference state before checking agreement. A sensor model can include a delay or mixing volume that an algebraic reference omits. Align both acquisition time and location before interpreting a difference as calibration error.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.