The simQ.y trace ranges from -31.481 to 438.107 across 101 saved checkpoints. It begins at 387.916 and finishes at -31.481 after 10,036,379 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

The largest change in simQ.y between saved samples lies between simulation times 18,808,536.2 s and 18,908,900 s. The channel moves from 438.107 to -31.481 across that interval. A finer export is needed to resolve what happens between those observations.

The component declarations name sou (Boundary p T), bou (Mass Flow Source T), sou1 (Boundary p T), bou1 (Mass Flow Source T). The source declares pvtTyp = , T_start = 30.65195319 + 273.15, eleLosFac = 0.09, til = 0.78539816339745. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. simQ.y begins at 387.92 and ends at −31.481. meaQ.y begins at 387.52 and ends at −11.597. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 18,808,536 to 18,908,900 seconds. Subtracting 438.107 from -31.481 gives -469.588 source units. Its location brackets the change within one saved interval of 100,364 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

simQ.y (source units)

meaQ.y (source units)

8872521

387.9157

387.5237

8972885

438.1065

387.5237

1.08798e+07

438.1065

387.5237

1.288707e+07

438.1065

387.5237

1.489435e+07

438.1065

387.5237

1.690162e+07

438.1065

387.5237

1.880854e+07

438.1065

387.5237

1.89089e+07

-31.48118

-11.59744

What to check on site

Keep voltage, current, real power and energy distinct. Establish the reference direction at the measurement terminal before interpreting a sign change as import or export. Compare the same load boundary and duration in site data and the simulation.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Checking the two recorded channels

At 18,908,900 s, simQ.y reads -31.481 and meaQ.y reads -11.597. Across the run, the second channel ranges from -11.597 to 387.524. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.